BD-5000 Syringe Pump-Brand Meditech Syringe & Infusion Pump-Brand Meditech (Asia) Co., Ltd.

bet36体育

  • <tfoot id="ghfdf"></tfoot>
  • <p id="ghfdf"><em id="ghfdf"><figure id="ghfdf"></figure><noscript id="ghfdf"><mark id="ghfdf"></mark></noscript></em></p>
    <i id="ghfdf"></i>

  • <input id="ghfdf"><canvas id="ghfdf"></canvas></input>

        BD-5000 Syringe Pump
        Time:2018-7-6 14:45:11Access:
        BD-5000 Syringe Pump

        Brand Meditec Model: BD-5000 syringe pump technical specification:

         

        Maxim. Injection rate: 1500 ml/h (Different syringes have different maximum rate)

        Applicable syringes: All brands of standard syringes: 5, 10, 20, 30 and 50 (60) ml

        Drug library: More than 20 drug names: Penicillin, Vancomycin, Pitocin, Insulin, Lidocaine, Heparin, Atropin, Dopamine, Epinephrine etc.

        Power supply: AC100-240V.50/60HZ

        Gross weight: 3.0kg

        Battery: Rechargeable lithium polymer battery 7.4V, 1600mA working for 4 hours (5ml/h) after being fully charged

        Max power consumption: 25VA

        Accumulated volume: 0.1~9999.9ml

        Injection accuracy: ±3% (after being well adjusted, up to ±2%)

        Injection increment: 0.1ml/h

        Preset range: 0.1~9999.9ml

        Classification: Class II, type BF

        Injection rate range: 5ml: 0.1ml/h---100ml/h    10ml: 0.1ml/h---200ml/h

        20ml: 0.1ml/h---400ml/h   30ml: 0.1ml/h---600ml/h

        50 (60) ml: 0.1ml/h---1500ml/h

        Bolus rate: 5ml: 100ml/h   10ml: 200ml/h   20ml: 400ml/h

        30ml: 400-600ml/h   50ml: 400-1500ml/h

        Alarm function: NEAR, OVER, OCCL., syringe disengaged, no AC power supply, low battery, serious low battery, error 1/2/3, preset volume alarm

        Selectable modes: 1. Rate Mode   2. Time Mode   3. Body Weight Mode

        Time mode: Volume limit: 0.1-999.9ml  Time: 1-2000min

        Body weight mode: Body weight: 0.1300kg      Drug limit: 0.1999.9mg

        Volume limit: 0.1999.9ml  Dose: 0.19999.9(subject to unit, dosage, liquid, weight and syringe) Unit: mg/kg/h, ug/kg/min

        Occlusion value: 0.04Mpa-0.16Mpa

        KVO rate: Adjustable range: 0.1ml/h-5.0ml/h, choose OFF to cancel

        EMC: Meet the requirements of IEC60601-1-2(2007 version)

        Electrical safety: Meet the requirements of EN60601-1:1990+A1:1993+A2:1995

         

        Two CPU 